Care and maintenance

How coated sheet should be handled, installed, cleaned and inspected. These are the guidelines referred to in the RANGEFABRIKEN warranty terms.

Scope

The guidelines cover RANGEFABRIKEN's coil-coated products for building and facades: RANGE Bendo, Steelgrade, INDUGRADE, CCA and CCS, as well as roof drainage coated by RANGEFABRIKEN. They do not apply to sign substrates such as RANGE A, RANGE PLUS and Bond, where the surface is used indoors or processed further by the customer.

Handling and installation

Most of what goes wrong with a coated surface goes wrong before the sheet is installed. Fingerprints, grease and small scratches from tools remain visible for a long time, and a scratch down to the metal is a starting point for corrosion.

When handling the sheet

  • Wear protective gloves. Grease from hands settles in the paint and is particularly visible on dark and matt colours.
  • Lift instead of dragging. A sheet dragged over another gets scratched by its edge.
  • Leave the protective film on for as long as possible, but no longer than necessary. Film left in the sun becomes difficult to remove.

When installing

  • Use clean tools with protected contact surfaces.
  • Choose fasteners in a material compatible with the sheet. Different metals in contact with each other cause galvanic corrosion, and aluminium is sensitive to copper.
  • Bend with a radius tool and check the result on a test piece before running the series. Different paints and materials behave differently when bent.

Coated sheet must always be test-bent and tested in the application it is intended for. This is a prerequisite for the warranty, and it is also the quickest way to find out whether the choice of material needs adjusting.

The environment the sheet is installed in

The warranty applies in a normal outdoor environment. What falls outside it is not arbitrary: these are environments where no coated sheet lasts as long.

  • Chemicals and solvents can break down or discolour the paint. If the surface is exposed to anything of this kind, rinse immediately with clean water and mild soap.
  • Contact with copper, zinc or wet concrete must be avoided. This also applies to water that has run over such materials before reaching the sheet.
  • High temperatures over long periods can cause cracking or deformation. The sheet withstands a wide temperature range, but not just anything.

Cleaning

Surfaces washed by rain largely look after themselves. The problem is the surfaces that are not: undersides, surfaces under roofs and areas behind vegetation. There, dirt remains and holds moisture against the paint.

How often

At least twice a year. In coastal locations and near industry or heavy traffic, more often. Surfaces never reached by rain always need to be cleaned manually.

How

  • Soft cloth or sponge with a mild soap solution, pH 5 to 9, and lukewarm water.
  • No abrasives, no strong solvents and no pressure washing.
  • Rinse thoroughly with clean water so that no cleaning agent is left behind.
  • Dry with a soft, dry cloth to avoid water spots and limescale deposits.

Preferably use a biodegradable cleaning agent. Whatever is rinsed off the facade ends up in the ground around the building.

Inspection and remedial action

An annual inspection is a condition of the warranty, and does not take long. What you are looking for is damage that lets moisture in under the paint.

  • Check the surface for scratches, chips and blisters.
  • Check edges and joints in particular. That is where damage occurs first.
  • Small scratches are repaired with matching touch-up paint according to the manufacturer's instructions.
  • For more extensive damage, a professional assessment should be made before any action is taken. Sometimes recoating is the right answer, sometimes replacing the sheet.

It is a good idea to document the inspection. Being able to show that maintenance has been carried out makes a warranty claim considerably simpler.

Maintenance and service life

A coated surface that is looked after keeps both its protection and its appearance, and does not need repainting as often. That is both cheaper and better for the environment than early replacement.

Both aluminium and steel are fully recyclable. When the sheet is eventually replaced, it should go to metal recycling and not to mixed construction waste.

Unsure about an application?

Ask us